Phone 1300 781 620

Interlink Retaining Wall Systems - Specifications


Designed to retain level ground

Height Footing Type Surface Slope Surcharge Load KPA Drainage Type Depth of Drainage (Area A) Backfill Material (Area B)
600mm A Level Nil Aggregate 150mm Sandy Loam
700mm B Level Nil Aggregate 150mm Sandy Loam
800mm B Level Nil Aggregate 150mm Sandy Loam
800mm C Level 2.5 NFC 200mm Sandy Loam
900mm B Level Nil Aggregate 200mm Aggregate
1000mm C Level 2.5 NFC 300mm Sandy Loam
1200mm C Level 2.5 NFC 400mm Sandy Loam
1400mm C Level 2.5 NFC 500mm Sandy Loam
1600mm C Level 5.0 NFC 700mm Sandy Loam
1800mm C Level 5.0 NFC 800mm Sandy Loam

Designed to retain a 1:4 slope

Height Footing Type Surface Slope Surcharge Load KPA Drainage Type Depth of Drainage (Area A) Backfill Material (Area B)
600mm B 1:4 Nil Aggregate 150mm Sandy Loam
700mm B 1:4 Nil Aggregate 200mm Sandy Loam
800mm B 1:4 Nil Aggregate 200mm Aggregate
800mm C 1:4 2.5 NFC 250mm Sandy Loam
900mm C 1:4 2.5 NFC 350mm Sandy Loam
1000mm C 1:4 2.5 NFC 450mm Sandy Loam
1200mm C 1:4 2.5 NFC 600mm Sandy Loam
1400mm C 1:4 5.0 NFC 800mm Sandy Loam
1600mm C 1:4 5.0 NFC 900mm Sandy Loam

NFC = No Fines Concrete.

Sharp drainage gravel. 15 to 20mm, mixed with cement 5:1 ratio minimum water (No fines or sand).

Aggregate: = 10 - 25mm sharp drainage aggregate.